FREE EU SHIPPING on €70+ orders
Lifetime Warranty See details
Visit our showrooms
The price is valid only for the online store and may differ from the prices in retail stores.

Magnification: 40–1000x. Trinocular head, plan achromatic and plan fluorite objectives, reflected light source – 100W mercury lamp, transmitted light source – 30W halogen lamp, Köhler illumination in reflected and transmitted light

Trinocular
The microscope head is a core element of the microscope that you look through to see a magnified sample
40–1000 basic (*optional: 40–1250/1500/2000/2500)
How much the size of a sample increases when you observe it through a microscope
Laboratory/medical
Application and use of the microscope
Availability

Product ID 82904
Brand MAGUS
Warranty 5 years
EAN 5905555018140
Package size (LxWxH) 45x30x96 cm
Shipping Weight 16.5 kg
Description

Fluorescence microscope MAGUS Lum 400 is designed for diagnostics and research by methods of fluorescence (reflected light) and brightfield (transmitted light) microscopy. Darkfield, phase contrast, and polarization techniques can be used with optional equipment. Areas of application of fluorescence microscope: DNA analysis, study of pathogens, sanitary and epidemiological surveillance, forensic examination, etc.

Optics

This is a trinocular microscope: The binocular head is 30° inclined and the digital camera (not included) is installed in the trinocular tube. As the eyepiece tubes are 360° rotatable, it is easy to adjust them to fit the height of the user.

Five objectives can be installed in the revolving eyepiece. Four infinity plan achromatic objectives are included. One of them, a fluo objective with a 40x magnification, is designed for fluorescence observations. 4x, 10x, and 100x objectives are used for the brightfield microscopy technique. An additional objective can be mounted in the free slot of the revolving nosepiece to achieve extra magnification within the magnification range of the microscope.

The revolving nosepiece with objectives is oriented toward the interior – the user can see the objective inserted into the optical path.

Illumination

The reflected light source is a 100W mercury lamp. It is placed inside the lamphouse, which provides efficient heat dissipation: The lamp does not overheat even during long hours of operation. The lamp can be centered along three axes to provide the optimal illumination of the working area. If you need to replace it, it will be fairly easy to remove and install the bulb. The mercury lamp is suitable for fluorescent dyes because it has discrete peaks. The reflected light illuminator contains four excitation filters: ultraviolet (UV), violet (V), blue (B), and green (G).

Transmitted light source: 30W halogen bulb. It is bright enough to work with any objectives of any magnification. Thanks to the color temperature of the illumination, even long observations will not strain the eyes. The illumination system also includes a condenser. It has a slot for a slider (phase contrast or darkfield).

In transmitted and reflected light, you can set up the Köhler illumination method. When the illumination is set up in this way, there is no darkening at the edges, the sample is clearly visible, and the image artifacts are removed.

Stage and focusing mechanism

The microscope is equipped with an ergonomically designed stage without a positioning rack. When observing in reflected light, a black stage plate is placed on the stage to remove stray light. The specimen holder is removable and can be taken out, if necessary, by loosening two screws. The focusing knobs are coaxial and located on each side of the microscope. Coarse focusing has a lock knob and tension adjustment and fine focusing is used for focus adjustment.

Accessories

The MAGUS Lum 400 microscope can be equipped with additional accessories: digital camera, phase contrast device, polarization device, darkfield condenser, eyepieces and objectives, darkfield and phase contrast sliders. For measuring objects, the configuration can be supplemented with a calibration slide.

Key features:

  • Microscopy techniques: fluorescence in reflected light, brightfield in transmitted light
  • Other research methods with optional accessories: phase contrast, simple polarization, darkfield
  • Trinocular head with a trinocular tube for mounting a digital camera; 360° rotatable eyepiece tubes
  • Infinity plan achromatic objectives, including a fluo objective
  • Reflected light source: 100W mercury lamp, transmitted light source: 30W halogen lamp
  • Köhler illumination method in transmitted and reflected light
  • Fluorescence filters: ultraviolet (UV), violet (V), blue (B), green (G)
  • Ergonomic stage with a removable specimen holder and no positioning rack

The kit includes:

  • Base with a power input, transmitted light source and condenser, focusing mechanism, stage, and revolving nosepiece
  • Reflected light illuminator
  • Mercury lamphouse
  • Trinocular head
  • Infinity plan achromatic objective: PL 4x/0.10 WD 19.8mm
  • Infinity plan achromatic objective: PL 10x/0.25 WD 5.0mm
  • Infinity plan achromatic objective, fluo: PL FL 40x/0.85 (spring-loaded) WD 0.42mm
  • Infinity plan achromatic objective: PL 100x/1.25 (spring-loaded, oil) WD 0.36mm
  • Eyepiece 10x/22mm with long eye relief (2 pcs.)
  • UV shield
  • C-mount adapter 1x
  • Hex key wrench
  • Mercury lamp power supply
  • Power cord
  • Reflected light illuminator power cord
  • Dust cover
  • User manual and warranty card

Available on request:

  • 10x/22mm eyepiece with a scale
  • 12.5x/14mm eyepiece (2 pcs.)
  • 15x/15mm eyepiece (2 pcs.)
  • 20x/12mm eyepiece (2 pcs.)
  • 25x/9mm eyepiece (2 pcs.)
  • Infinity plan achromatic objective, fluo: PL FL 10x/0.35 WD 2.37mm
  • Infinity plan achromatic objective: PL 60x/0.80 ∞/0.17 WD 0.46mm
  • Phase contrast device
  • Darkfield condenser
  • Immersion darkfield condenser
  • Darkfield slider
  • Polarization device
  • Digital camera
  • Calibration slide
Specifications
Product ID 82904
Brand MAGUS
Warranty 5 years
EAN 5905555018140
Package size (LxWxH) 45x30x96 cm
Shipping Weight 16.5 kg
Type biological, light/optical
Head trinocular
Nozzle Gemel head (Siedentopf, 360° rotation)
Head inclination angle 30 °
Magnification, x 40–1000 basic (*optional: 40–1250/1500/2000/2500)
Eyepiece tube diameter, mm 30
Eyepieces 10х/22mm, eye relief: 10mm (*optional: 10x/22mm with scale, 12.5x/14; 15x/15; 20x/12; 25x/9)
Objectives infinity plan achromatic and fluo objectives: PL 4x/0.10, PL 10x/0.25, PL FL 40x/0.85, PL 100x/1.25 (oil); parfocal distance 45mm (*optional: PL FL 10x/0.35, PL 60x/0.80 ∞/0.17)
Revolving nosepiece for 5 objectives
Working distance, mm 19.8 (4x); 5.0 (10x); 0.42 (FL 40x); 0.36 (100x); 2.37 (FL 10х); 0.46 (60х)
Interpupillary distance, mm 48 — 75
Stage, mm 180x150
Stage moving range, mm 75/50
Stage features two-axis mechanical stage, without a positioning rack
Condenser Abbe condenser, N.A. 1.25, center-adjustable, height-adjustable, adjustable aperture diaphragm, a slot for a darkfield slider and phase contrast slider, dovetail mount
Diaphragm adjustable aperture diaphragm, adjustable iris field diaphragm
Focus coaxial, coarse focusing (21mm, 39.8mm/circle, with a lock knob and tension adjusting knob) and fine focusing (0.002mm)
Illumination halogen, fluorescent
Brightness adjustment
Power supply AC network, 85–265V, 50/60Hz
Light source type reflected light: 100W mercury lamp; transmitted light: 12V/30W halogen lamp
Light filters yes
Operating temperature range,°C 5...+35
Ability to connect additional equipment phase contrast device (condenser and objectives), darkfield condenser (dry or oil), polarization devices (polarizer and analyzer), darkfield slider
User level experienced users, professionals
Assembly and installation difficulty level complicated
Fluorescent module filters: ultraviolet (UV), violet (V), blue (B), green (G)
Fluorescence filter: filter type, excitation wavelength/dichroic mirror/emission wavelength ultraviolet (UV), 320–380nm/425 nm/435 nm; violet (V), 380–415nm/455nm/475nm; blue (B), 450–490nm/505nm/515nm; green (G), 495–555nm/585nm/595nm
Application laboratory/medical
Illumination location dual
Research method bright field, fluorescence
Pouch/case/bag in set dust cover
Reviews
Frequently Asked Questions – Microscopes (20.04.2020)
We have gathered answers to the most frequently asked questions to help you sort things out
Eye under a microscope: insects’ photo (20.04.2020)
Find out why studying eyes under a microscope is entertaining; how insects’ and arachnids’ eyes differ and what the best way is to observe such an interesting specimen
What does hair look like under a microscope? (17.05.2020)
Read this review to learn how to observe human hair, what different hair looks like under a microscope and what magnification is required for observations
How does the aperture of a microscope objective lens work? (17.05.2020)
Learn what a numerical aperture is and how to choose a suitable objective lens for your microscope here
A spider under a microscope: photos and peculiarities of studying the slide (18.05.2020)
Learn what a spider looks like under microscope, when the best time is to take photos of it, how to study it properly at magnification and more interesting facts about observing insects and arachnids
What does a microscope consist of? (18.05.2020)
This review for beginner explorers of the micro world introduces you to the optical, illuminating and mechanical parts of a microscope and their functions
Paramecium caudatum - your first friend from the microworld (21.11.2016)

Short article about Paramecium caudatum - a microorganism that is interesting to observe through any microscope

Questions and Answers
Submit your question
Your name *
E-mail *
Your question / comment *